CISA Warns of Iskra iHUB Authentication Vulnerability Allowing Remote Attackers to Reconfigure Devices

CISA has issued a critical security alert regarding a severe authentication vulnerability affecting Iskra iHUB and iHUB Lite smart metering gateways deployed worldwide in energy infrastructure.

The flaw enables remote attackers to reconfigure devices and manipulate connected systems without requiring any credentials, posing significant risks to critical infrastructure operations.

The vulnerability, tracked as CVE-2025-13510, stems from missing authentication controls on the device’s web management interface.

This allows unauthenticated users to access and modify critical device settings, including firmware updates and system configurations.

The vulnerability has been assigned a CVSS v4 score of 9.3, indicating critical severity with remote exploitability and low attack complexity.

No user interaction is required for exploitation, making this a particularly dangerous threat to unprotected deployments.

Iskra, a Slovenian company specializing in smart metering infrastructure, has not responded to CISA’s coordination requests regarding this vulnerability.

The affected products include all versions of iHUB and iHUB Lite devices deployed globally. Given the widespread deployment of these devices in energy sectors across multiple countries, the potential impact on critical infrastructure operations remains substantial.

CVE IDCVSS v3.1 ScoreCVSS v4 ScoreVulnerability TypeAttack VectorAuthentication Required
CVE-2025-135109.19.3Missing Authentication for Critical Function (CWE-306)Network/Adjacent NetworkNone

The vulnerability was reported by researcher Souvik Kandar to CISA. Currently, no known public exploitation targeting this vulnerability has been documented, though the ease of exploitation suggests active discovery and potential abuse remains likely if mitigation measures are not promptly implemented.

CISA recommends organizations adopt immediate defensive measures to minimize exploitation risk.

Critical recommendations include minimizing network exposure by ensuring control system devices are not accessible from the Internet, deploying firewalls to isolate control system networks from business systems, and implementing secure remote access through Virtual Private Networks when necessary.

Organizations should also perform thorough impact analysis before deploying defensive measures to ensure operational continuity.

The agency emphasizes implementing defense-in-depth strategies and proactive cybersecurity measures across industrial control system infrastructure.

Organizations suspecting malicious activity should report findings to CISA for threat tracking and correlation analysis.