Critical OpenSSH Vulnerability Exposes Moxa Ethernet Switches to Remote Code Execution

Moxa has released a critical security advisory addressing a severe vulnerability in its Ethernet switches that could allow attackers to execute arbitrary code remotely.

The vulnerability, identified as CVE-2023-38408, stems from an incomplete fix to an earlier OpenSSH security issue and affects multiple product lines across the manufacturer’s industrial networking portfolio.

The flaw lies in the PKCS#11 feature of OpenSSH’s ssh-agent, which uses an unreliable search-path mechanism.

This design weakness enables remote code execution if an agent is forwarded to an attacker-controlled system.

The vulnerability is particularly dangerous in industrial environments, where Ethernet switches are critical components of the network infrastructure.

An attacker exploiting this vulnerability could gain complete system control, compromising both confidentiality, integrity, and availability of affected devices.

According to Moxa’s security advisory MPSA-256261, the vulnerability has a CVSS 3.1 score of 9.8, indicating critical severity.

The threat can be exploited remotely without authentication, requiring no user interaction or special privileges.

The vulnerability represents an incomplete remediation of CVE-2016-10009, indicating that initial patch efforts did not fully address the underlying design flaw in OpenSSH’s code search mechanisms.

Multiple product series from Moxa’s industrial switching portfolio are affected by this vulnerability. The EDS-G4000, EDS-4008, EDS-4009, EDS-4012, EDS-4014, EDS-G4008, EDS-G4012, and EDS-G4014 series running firmware version 4.1 and earlier are vulnerable.

Additionally, the RKS-G4000, RKS-G4028, and RKS-G4028-L3 series with firmware v5.0 and earlier require immediate patching.

Moxa has developed security patches to address the vulnerability across affected product lines. Organizations utilizing these switches should contact Moxa Technical Support immediately to obtain the necessary firmware updates.

The patched firmware versions are v4.1.58 for the EDS series and v5.0.4 for the RKS series. Given the critical nature of this vulnerability and its potential for unauthenticated exploitation, applying these patches should be treated as a priority security operation.

CVE IDVulnerability TypeCVSS ScoreSeverityExploitability
CVE-2023-38408CWE-428: Unquoted Search Path9.8CriticalUnauthenticated, Network-based

Organizations operating Moxa Ethernet switches in production environments should review their asset inventory and initiate firmware upgrade procedures.

The vulnerability’s critical rating and remote exploitability without authentication make it a high-priority remediation target for industrial network administrators responsible for maintaining the security posture of critical infrastructure systems.

Follow us on Google News , LinkedIn and X to Get More Instant Updates. Set Cyberpress as a Preferred Source in Google.